Opentec RPT 7 Ruggedisation
| Meets or exceeds the following durability standards: |
| Drop |
MIL-STD 810F - 516.5, Procedure IV (3ft drop test) |
| Vibration |
MIL-STD 810F - 514.5, Procedure I, Category 24,
Figure 514.5C-17 & 514.5C-18; and
ASTM 4169-99 - Truck Assurance Level II, Schedule E
|
| Water |
MIL-STD 810G - 506.4 Procedure II; and
IEC 60529 Edition 2: 2001/2 - IPX4
|
| Humidity |
MIL-STD 810G - 507.4 Procedure I (Storage) &
Procedure II (Operational); and
IEC 60529 - IPX4
|
| Dust |
IEC 60529 Edition 2: 2001/2 - IP5X
|
| Thermal Shock |
MIL-STD 810F - 503.4, Procedure I (Operational) &
II (Non-Operational)
|
| Temperature |
MIL-STD 810F - 501.4, Procedure I (Storage) &
II (Operational) for high temperature; and
MIL-STD 810F - 502.4, Procedure I (Storage) &
II & III (Operational) for low temperature
|
| Altitude |
MIL-STD 810F - 500.4, Procedure I (Storage) &
II (Operational)
|
Combined
IP Rating * |
IP54 |
EMC &
Electrical Safety |
EN 300 328 V.1.6.1 (2004-11)
EN 301 489-1 V.1.4.1 (2005-09)
EN 301 489-17 V.1.6.1 (2002)
EN 50371: 2002
|
| Meets the following operational ratings: |
| Durability |
FULLY RUGGED
>> learn more about what this means |
| Temperature |
Operating: -20C to 60C
(Storage: -55C to 75C) |
| Humidity |
Operating: 5% to 95%
|
|